MIL-DTL-45195F (AR)
primer lot and the assembly of that lot into cartridges
exceeds three years, or if the M28 primers have been subjected
to adverse conditions, however brief, at any time since
previous tests, the applicable lot shall be subjected to and
must satisfactorily pass the check test for deterioration
specified in 4.4.4, immediately before the M28 primer lot is
assembled into cartridges (see 6.21).
3.15.1 Non-functioning. The head assembly shall not
function by an applied energy of 47.52 inch-ounces minimum
(min).
3.15.2 Functioning. The head assembly shall function by
applied energy of 159.20 inch-ounces maximum (max).