MIL-DTL-46229D (AR)
TABLE II. First article inspection.
Inspection
Number of FAT
Requirement
Examination or Test
Method
Samples
Paragraph
Reference
Cartridge, 105MM, Blank, M395,
Assembly
(Dwg 7549251)
Examination for defects
20
3.2
4.3.2.5-4.3.2.8
20
3.5
Proving Ground (1/)
4.3.2.9
Cup, Closing
(Dwg 7549253)
10
3.2
4.3.2.1
Examination for defects
Wad, Closing
(Dwg 7549252)
10
3.2
4.3.2.2
Examination for defects
Case, Cartridge, 105MM, Blank
(Dwg 8845003)
10
3.2
4.3.2.3
Examination for defects
Primer, Percussion
(Dwg 8839474)
10
3.2
4.3.2.4
Examination for defect
Container, Fiber
(Dwg 7549255)
10
3.2
4.3.2.10,
Examination for defect
4.3.2.11
Box, Wood
(Dwg 7549254)
4.3.2.12,
10
3.2
Examination for defect
4.3.2.13
NOTES:
1/ After inspection as per 4.3.2.5 - 4.3.2.8, twenty (20) of the forty-five (45) inspected cartridges
shall be selected at random for proving ground tests.
6