MIL-DTL-46229D (AR)
Drawing Number
7549255
4.3.2.11
Fiber container (sealed container).
Next Higher Assembly
7549254
Conformance
Requirement
Classification
Examination or Test
Inspection Method Reference
Criteria
Paragraph
Critical
None defined
Major
Tape incomplete or inner layer not in
VL-IV
3.2
Visual
101
contact with the surface of the container
for at least ½ inch on each side of joint.
Metal end loose or distorted
VL-IV
3.2
Manual
102
Container damaged through all
3.2
VL-IV
Visual
103
impregnated asphalt layers as evidenced
by removing each layer of suspected
container.
DODIC marking missing, incorrect or
104
3.2
VL-IV
Visual
illegible
Minor
Length of tear tab, min.
3.2
VL-II
201
Visual
Color of tape incorrect.
3.2
VL-II
202
Visual
Marking misleading or unidentifiable.
3.2
VL-II
203
Visual
Cut, scuffs or gouges in outer layer.
3.2
VL-II
204
Visual
Gap between body and cover of
3.2
VL-II
205
Visual/AIE
container exceeding 1/8 inch.
206
Contents loose upon shaking.
VL-II
3.2
Manual
13