MIL-DTL-14852D (AR)
Conformance inspection by classification of characteristics
PARAGRAPH
TITLE
DRAWING NUMBER
4.3.2.2
Base plug (prior to painting)
SHEET 1 OF 2
10534903
NEXT HIGHER
ASSEMBLY
10534900
CLASSIFICATION
EXAMINATION OR TEST
CONFORMANCE
REQUIREMENT
INSPECTION
CRITERIA
PARAGRAPH
METHOD
REFERENCE
Critical
1
Metal defective
100%
3.5.3
4.4.5
(Note 1)
Major
101
Runout of force fit surface with large
Level IV
3.2
AIE
outside diameter
102
Perpendicularity of front face of
Level IV
3.2
AIE
flange with force fit surface
103
Diameter of force fit surface
Level IV
3.2
AIE
104
Diameter of large outside surface
Level IV
3.2
AIE
105
Depth of undercut max
Level IV
3.2
AIE
106
Length of force fit surface
level IV
3.2
AIE
107
Length total
level IV
3.2
AIE
108
Thickness through base, min
Level IV
3.2
AIE
109
Width of undercut
Level IV
3.2
AIE
110
Finish on force fit surface improper
Level IV
3.2
Visual
111
Yield strength and percent elongation
4.4.1.2.2
3.3.2
4.4.1.2.2
112
Protective coating (salt spray)
4.4.4
3.2
4.4.4
113
Macro etch
4.4.2
3.2
4.4.2
Note 1. The critical characteristic shall undergo 100% screening. In addition, apply Level VII
inspection IAW the critical characteristics paragraph of MIL-STD-1916.