MIL-DTL-20354D (AR)
Conformance inspection by classification of characteristics
DRAWING NUMBER
PARAGRAPH
TITLE
SHEET 1 OF 1
9206746
4.3.2.3
Illuminating canister and parachute
assembly, prior to crimping
NEXT HIGHER
ASSEMBLY
CLASSIFICATION EXAMINATION OR TEST
CONFORMANCE
REQUIREMENT
INSPECTION
CRITERIA
PARAGRAPH
METHOD
REFERENCE
Critical
None defined
Major
101
Length of center wire
Level IV
3.2.3
AIE
Minor
201
Staking missing or improper assy. of
Level II
3.2.3
Visual
swivel nut
202
Wire not frayed or improperly
Level II
3.2.3
Visual
soldered
203
Evidence of poor workmanship
Level II
3.6
Visual
17