MIL-DTL-60315C (AR)
Conformance inspection by classification of characteristics
DRAWING NUMBER
TITLE
PARAGRAPH
9205472 or 9288695
Charge, Assembly
SHEET 1 OF 1
4.3.2.4
NEXT HIGHER ASSEMBLY
VERIFICATION
REQUIREMENT
PARAGRAPH REFERENCE/
CATEGORY
EXAMINATION OR TEST
LEVEL or %
PARAGRAPH
INSPECTION METHOD
Critical
Missing or incorrect increments or incorrect
100% (see Note 1)
3.4
Scale (see 4.4.1)
1
propelling charge assembly weight
Major
101
Incorrect sequence of increments
100%
3.2
Visual
Assembly damaged to the extent that
Visual
100%
3.2
102
propellant can escape
Minor
201
Increments insecurely tied at junctions
II
3.2
Visual
202
Ties loose, broken or insecurely tied
II
3.2
Visual
203
Marking missing or unidentifiable
II
3.2
Visual
204
Evidence of poor workmanship
II
3.5
Visual
1/ The defect shall be classified critical when the excess in weight is more than 3 times the allowable tolerance as specified in 3.4. (See 6.9). Major when the weight is in
excess of that in 3.4 but not greater than 3 times. Compliance with 3.4 shall be determined by using the average weight of the empty bag assembly. If the charges are
assembled in accordance with 9205472 and the defect is determined to be due to an incorrect propelling charge assembly weight, remove increment 5 by raising it off the
scale without breaking the cord and replace it with a weight representing the average weight of increment 5. If the weight is incorrect, reject the charge. If the weight is
correct and it can be determined that the off weight of increment 5 is caused by the lead foil (tare weight of bag) the charge shall be considered acceptable.