MIL-DTL-70526B (AR)
TABLE II First article inspection
Number of
REQUIREMENT
INSPECTION
FAT Samples
PARAGRAPH
METHOD
REFERENCE
Delay assembly
(Drawing 12926809)
Examination for defects (Note 1)
30
3.2
4.3.2.1-4.3.2.6
Delay housing crimp test
5/machine
3.5
4.4.4
Pilot composition test
150
3.8.1
4.4.6.1
Note 1. The examination for defects in paragraph 4.3.2 in many cases must be verified
during assembly.
8